Fabrication of MnO2 - based electrochemical electrodes for the determination of copper (II) ion in water

Huyen Thi Thu Nguyen, Dung Anh Viet Dang, Trang Hong Tran Pham, Huy Khanh Pham, Cuong Van Pham

Abstract


Porous MnO2 with a hexagonal crystalline structure was facilely prepared at a low hydrothermal temperature of 90°C, without using any template or capping agent. The as-prepared MnO2 only presented an exceptional electrocatalytic ability by the typical amperometric detection of copper (II) in the presence of super P carbon black as  conducting agent, and Nafion as binder. In the present work, to evaluate the detection ability of copper (II) of the MnO2, the graphite plate electrodes (GPE) were modified with MnO2 microflowers and super P carbon and used as electrochemical electrodes for the determanation of copper (II) present in water sources. From the measured results, the fabricated electrodes with excellent copper detection and rapid response demonstrated has high application potential for electrochemical sensors in detection of copper in water resources.

Keywords


MnO2; copper ions; graphite plate; electrochemical sensor

Full Text:

PDF

References


Y.C. Sharma, V. Srivastava, V.K. Singh, S.N. Kaul, C.H. Weng, Environmetal Tech. 30-6 (2009) 583-609.

https://10.1080/09593330902838080.

M. Hua, S. Zhang, B. Pan, W. Zhang, L. Lv, Q. Zhang, J. Hazard. Mat. 211-212 (2012) 317-321.

B. Bansod, T. Kumar, R. Thakur, S. Rana, I. Singh, Biosens. Bioelectron. 94 (2017) 443-455. https://doi.org/10.1016/j.bios.2017.03.031

Y. Wei, C. Gao, F.-L. Meng, H.-H. Li, L. Wang, J.-H. Liu, X.-J. Huang, J. Phys. Chem. C 116 (2012) 1034-1041.

https://doi.org/10.1021/jp209805c.

Y. Sun, W. Zhang, H. Yu, C. Hou, D.-s. Li, Y. Zhang, Y. Liu, J. Alloys Compd. 638 (2015) 182-187. https://doi.org/10.1016/j.jallcom.2015.03.061

S. Hao, J. Li, Y. Li, Y. Zhang, G. Hu, Anal. Methods, 8 (2016) 4919-4925.

https://10.1039/c6ay01224h

M. Majidian, J.B. Raoof, S.R. Hosseini, R. Ojani, J. Iran. Chem. Soc. 14 (2017) 1263-1270.

WHO, Guidelines for Drinking-water Quality 3nd ed., Geneva, World Health Organization, 2008.

V.N.t.r.o.D.W. Quality, Vietnam National technical regulation on Domestic Water Quality, Ministry of Health, 2018, p. 22

G. Alpdoğan, Ş.D. Zor, J. AOAC Int 100 (2019) 1524-1530.

Q.-X. Zhang, H. Wen, D. Peng, Q. Fu, X.-J. Huang, J. Electroanal. Chem. 739 (2015) 89-96.

https://10.1016/j.jelechem.2014.12.023.

M.Y. Wang, W. Zhu, L. Ma, J.J. Ma, D.E. Zhang, Z.W. Tong, J. Chen, Biosens. Bioelectron. 78 (2016) 259-266.

https://doi.org/10.1016/j.msec.2016.05.045

Y. Chen, K. Ma, J. Wang, Y. Gao, X. Zhu, W. Zhang, Mater. Res. Bull. 101 (2018) 56-60. https://doi.org/10.1016/j.materresbull.2018.01.013.

S. Zhao, T. Liu, D. Shi, Y. Zhang, W. Zeng, T. Li, B. Miao, Appl. Surf. Sci. 351 (2015) 862-868. https://doi.org/10.1016/j.apsusc.2015.06.045.

S.H. Mnyipika, T.S. Munonde, P.N. Nomngongo, Membranes 11 (2021) 517. https://doi.org/10.3390/membranes11070517

R. Gnanamuthu, C.W. Lee, Mater. Chem. Phys., 130 (2011) 831-834. https://doi.org/10.1016/j.matchemphys.2011.08.060.

H. Sha, Y. Wu, Y. Fan, Anal. Methods 9 (2017) 5618-5631.

https://doi.org/10.1039/C7AY01681F

H. Sun, C. Wang, Y. Xu, D. Dai, X. Deng, H. Gao, Chemistry Select 4 (2019) 11862-11871. https://doi.org/10.1002/slct.201902858




DOI: https://doi.org/10.51316/jca.2023.016

Refbacks

  • There are currently no refbacks.




*******

Index: Google ScholarCrossref

---------

Vietnam Journal of Catalysis and Adsorption

Address: Room 302  |  C4-5  |  Hanoi University of Science and Technology. 1 Dai Co Viet, Hanoi.

Tel.: ‎‎‎+84. 967.117.098 (Dr. Phượng)   Email: editor@jca.edu.vn   FB: JCA.VNACA