X-ray fluorescence equipment and method, nutrient content analysis in solid NPK compound fertilizer

Quynh Nguyen The, Nhiem Dao Ngoc, Huy Le Quang, Duong Nguyen Nhu, Kien Vu Duc, Cuong Nguyen Manh, Chuc Pham Ngoc, Long Nguyen The

Abstract


The paper presented two X-ray fluorescence analysis methods applicable to element content analysis in mixed fertilizers. The applied addition method determined the content of each ingredient in the fertilizer. The fundamental parameter method was applied for quick analysis, and at the same time, the content of ingredients on the fertilizer production line. X-ray fluorescence analysis methods and equipment have been researched and developed by the Institute of Materials Science - Vietnam Academy of Science and Technology and put into the gold and silver field for more than 30 years. The machines fabricated after 2014 applied TCVN 7055:2014, the 2nd edition "gold and gold alloys – Determination of gold content by X-ray fluorescence method". The national gold standard sample set, managed by the Vietnam Metrology Institute, was used to calibrate the machine, which has standard association with NIST (USA) and Krastsvetmet (Russia). Up to now, there are nearly 100 machines operating in more than twenty provinces and cities across the country, used to check the content of alloying components in gold jewelry processing, production and trading. The aim of new research and development in the field of fertilizers, in the coming time, is to transfer equipment and analysis methods to fertilizer production and trading enterprises.

Keywords


X-ray fluorescence (XRF); fertilizer; NH4H2PO4 - (MAP); KNO3; (NH4)2SO4 - (SA)

Full Text:

PDF

References


QCVN 01-189:2019/BNNPTNT. National technical regulation on fertilizer quality (2019).

TCVN 5815:2018. NPK mixed fertilizer - Test method (2018).

TCVN 9290:2012. Fertilizer - Determination of total lead by flame and electrothermal atomic absorption spectrometry, (2012).

Catalog Energy Dispersive X - Ray Fluorescence Spectrometer model VietSpace 5006, Institute of Materials Science, Hanoi (2009).

XRF FP Software Guide V. 4.6.0, www.amptek.com.

R. Tertian, F. Claisse. Anal. (1982) 223-225.

TCVN 10683:2015. Solid fertilizers - Preparation of the samples for chemical and physical analysis (2015).

TCVN 11409:2016. Solid fertulizers - Determination of citrate - insoluble phophorus content by gravimetric method (2016).

T. Q. Nguyen. PhD thesis, Institute of Physics and Electronics, Vietnam Institute of Science and Technology (2007) 37-40.

T. Q. Nguyen, Q. H. Le, N. D Nguyen, D. K. Vu, M. K. Nguyen, M. V. Tran, V. H. Nguyen, Vietnam J. Chem. (2017) 55(3e12), 56-61.

T. Q. Nguyen, Q. H. Le, T. D. Doan, N. D. Nguyen, D. K. Vu, M. C. Nguyen, X. T. Ngo, K. N. Phan, V. Q. Le, T. D. Tran., Vietnam J. Chem. (2019) 57(4e1,2), 152-156.




DOI: https://doi.org/10.51316/jca.2021.118